The RO60000 is a purification filter for laboratory and industrial use. See specification below.
Built to order, following consultation with manufacturer.
Specification:
Capacity: 6000GPD (Gallons Per Day) Working Pressure(PSI): 150-350PSI Pre-Filtration: (30" PP Cartridges 5u x7) Booster Pump: 7.5KW (10HP) Vertical Type Multi-stage Booster Pump - MAIN PUMP GRUNDFOSS Membrane Material: T.F.C with FRP outer wrap Membrane (Size x Unit): 8040 x 10 Membrane Housing Material: FRP Membrane Housing (Size x Unit): 8080 x 6 Flow Meters: Purewater / Wastewater Pressure Gauges: Feed water pressure / Booster pump outlet pressure gauges Water Quality Indicator: TDS meter with LCD Electrical Controls: Micro-computer control, overload breakers, LED indicators Frame Parts: Stainless Steel main frame Frame Size: 1150mm x 2300mm x 2150mm Frame Weight: 400kg
Replacement Filters:
Pre-Filters: 30" PP x 7
RO Membrane: TFC - BW8040 x 10
RO Membrane Housing: 8080 x 6
The RO membrane you use will depend on the water that will be passing through. There are 2 types, the TW-4040 and the BW-4040. The tap water (TW) and brackish water (BW) membrane elements are identical in physical dimension.
The outside of the BW membrane elements are fiberglass wrapped, while the TW membrane elements are only tape wrapped. When choosing between elements with or without a fiberglass outer shell, please consider that the membrane and element performance is the same between the two different element types. Due to structural strength, fiberglassed elements are recommended for systems with three or more elements in a single housing. Taped elements are recommended for systems with one or two elements per housing.
For more information on choosing a membrane click here.